McGuire

.

PLANT SUMMARY 

Containment 
Containment Type:                               Ice Condenser
Design Pressure:                                15 psig
Steam Generator 
Steam Generator Model: 
Number of Steam Generators:                     4
Number of Main Steam Isolation Valves:          4

Fuel 
No. of Fuel Assemblies:                         193
No. of Fuel Rods per Assembly:                  264 

Chemical and Volume Control System 
No. of Centrifugal Pumps:                       2
No. of Positive Displacement Pumps:             1
Pump Design Flow Rate:                          150 gpm @ 5800 ft
                                                98  gpm @ 5800 ft (PDP)

High Head (Safety) Injection System 
No. of Pumps:                                   2 (same as CVCS Centrifugal Charging Pumps)
Pump Design Flow Rate:                          150 gpm @ 5800 ft
Pump Shutoff Head:                              6000 ft 

Intermediate Head (Safety) Injection System 
No. of Pumps:                                    2
Pump Design Flow Rate:                          400 gpm @ 2600 ft
Pump Shutoff Head:                              1520 psi

Low Head (Safety) Injection System (LHI) 
No. of Pumps:                                   2
Pump Shutoff Head: 

Residual Heat Removal System 
RHR and LHI utilizes the same Pumps?            Yes 
No. of Pumps:                                   2
Pump Shutoff Head: 

Main Feedwater 
Condensate 
No. of Pumps:                                   3
Pump Shutoff Head:                              245 psig

Condensate Booster 
No. of Pumps:                                   3
Pump Shutoff Head:                              408.5 psig

Main Feedwater 
No. of Pumps:                                   2 Steam Driven

Startup Feedwater 
No. of Pumps:                                   None

Aux Feedwater System 
Number of Motor Driven Pumps:                   2 
Capacity:                                       450 gpm each 
Number of Turbine Driven Pumps:                 1 
Capacity:                                       900 gpm

Aux Feedwater Supply Source
Name:                                           Aux Feed CST (1 for both units) -- 42,500 gal 
Name:                                           Upper Surge Tanks 1A & 1B--85,000 total
Name:                                           Condenser Hotwell--170,000 gals 
                                                (at normal operating level)
Name:                                           Nuclear Service Water-- 1.8 x 108 gals 

Borated Water Sources and Design Capacities 
Name:                                           Four Accumulators 
Name:                                           Two Boric Acid Tanks 
Name:                                           Refueling Water Storage Tank--95,000 gal

Class 1E Emergency Power 
No. of Class-1E Diesel Generators (EDG):        4
      No. Shared per Plant Site:                0
      No. Dedicated per Unit:                   Two
      Diesel Manufacturers:                     Nordberg 
Other Sources of On Site Emergency Power:       None

GENERAL INFORMATION 

Plant Name: McGuire - Unit 1
Docket No.:  50-369
Owner/Operator:  Duke Power Company
Other Plants On Site:  McGuire - Unit 2
Site Location/Address:  17 miles Northwest of Charlotte, NC.
Facility Licensed Thermal Power Limit:          (Ref: License)  3411 MWt
Main Turbine Generator Rated Output:            1129 MWe
Ultimate Heat Sink - 
Supply to Main Turbine Condenser:               Lake Norman
Ultimate Heat Sink - 
Supply to  ECCS Service Water System:           Lake Norman/Standby Nuclear Service Water Pond (Two bodies of water serve as a heat sink for components cooled by the Nuclear Service Water system.  Lake Norman is the normal source of nuclear service water.  Should Lake Norman be lost due to a seismic event in excess of the design of Cowans Ford Dam; the Standby Nuclear Service Water Pond (SNSWP) would serve as the heat sink.)

PWR Type:                                       4-loop
NSSS Vendor:                                    Westinghouse 
Turbine Generator:                              Westinghouse
Arch. Engr.:                                    Duke Power Company
Constructor:                                    Duke Power Company
Date of Operating License Issuance:             07/08/81
Date of Commercial Operation:                   12/01/81